Waterlogic UV Ballast
Waterlogic UV Ballast
The Waterlogic ballast is used to power the UV lamp. The UV Ballast is situated inside the top half of your water cooler. When your UV lamp fails and your cooler signals UV fault, the general cause is the lamp itself, but on occasion (more common on older machines) the fault can be the UV ballast.
Compatable machines:
WL3000
WL2500
WL950
installation.
installation is relitivly simple.
- Power down your water cooler. (Remove plug from wall)
- Remove lid from water cooler. (This can be done by removing all relevant screws)
- Locate UV lamp and follow the wires until you reach the Ballast.
- Un-clip both wires attached to Ballast and remove screws.
- Replace old UV ballast with new and screw down.
- Clip-in both wires. (make sure to clip together the correct wires)
- Replace Water cooler lid and power up.
for further assistance please call: 0161 775 5691